Material Testing Machine with Thermostatic Chamber for Atmospheric Pressure ATCMT-8090


Features
The condensation is prevented by continuously flowing a certain amount of gas into the thermostat and preventing the inflow of air.
●At the operating temperature (-80 ºC to +90 ºC), the temperature is maintained during the test.
| Main Specifications | |
| Thermostat cooling method | Direct expansion refrigerant ultra-low temperature cooling system | 
| Thermostat heating method | Electric heater temperature control | 
| Temperature control range | -80 °C to +90 °C | 
| Thermostat internal dimensions | W340 × D560 × L550 mm | 
| External dimensions of testing machine | W1,050 × D520 × L2,800 mm | 
| Corresponding tests | Tensile test including the SSRT, High cycle fatigue test (HCF), Low cycle fatigue test (LCF) Fatigue crack growth test, Fracture toughness test Brittle fracture test (JIC, KIC), Programming test | 